Features
Standard requirements
WED dosimeter is a portable ergonomic equipment that consists in a storage system and transference of data:
- simultaneous measurement of the curves A and C
- exposure calculation TWA 8h, Dose and Thought out Dose
- measuring range from 40 to 140dB (A)
- scales: 40 a 120dB(A) / 60 a 140dB(A)
- peaks of 135,137 and 140 dB.
- battery life up to 50h


Wireless control dBWED
Using a notebook or a computer, you can configure the WED settings with the use of the dBWED software and analyse them in real time at a distance, enabling the user to monitor the measurement at a safe distance from the agents:
- simultaneous control of diverse WED dosimeters
- management of measurement setups
- recording of the measurement files
- viewing in real time of the measured data
- voice and written comments
dBLexd software
The processing data dBLexd software meets the requirements of all the national and international standards:
- compatible with the European Directive 2003/10/CE
- NR15, NHO01
- management of the measurements, setting the setups after the measurements, according to the user criteria
- calculation of the TWA, 8h according to the HEG (Homogeneous Exposure Group)
- management of the HEG – Homogeneous Exposure Group (tasks and operations)
- hearing protector attenuation, lunch hour cuts, …


Characteristics
- % DOSE, Thought out DOSE, LEq, LAVG, TWA
- built according to the standards: IEC 61252 (2002) /ANSI 1.25 (1991) / IEC 61672-1 (2002) / IEC 804 e 651, class 2
- measuring Scale: 40 to 140 dB(A)
- change rate: 3, 4 or 5
- calculated indicators: LAEq, LCEq, LASp, LAFp. LASpmax, LAFpmax, LASeq, LAFeq
- integration time: 1 second to 60 seconds
- storage capacity: 2GB of memory
- communication: Bluetooth
- operation temperature: 0ºC to 40ºC
- operation Humidity: 0 to 95% RH
- power supply: 1 rechargeable battery – up to 50h
- low battery indication
- auto run function: turns on and off automatically
- microphone: Type 2
- software: printing of the results according to the defined standards, noise dose evaluation, considering attenuation of the EPI, Languages: English, French, and Portuguese
- dimensions / weight: 105 x 60 x 25mm / 145g
Available packages
The packages of the WED dosimeter being sold are:
- KITW1C
- KITW1S
- KITW5C
- KITW5S
KITW1 or KITW5: Kit WED with 1 or 5 noise dosimeters
- S or C: With or Without acoustic calibrator
- includes: battery charger (1 or 5 Slots), Microphones (1 or 5 units), 1 Bluetooth key, certificates of conformity, dBWED and dBLexd operating manual, interactive training
- optional: calibration certificates, maintenance contract (technical support regarding spare parts, hotline, trainings, etc.).